Key result
Elective implantation of the Carbostent in patients at high risk of restenosis resulted in a 6-month event-free survival rate of 74% and a binary restenosis rate of 25%.
Why the study?
Does Carbostent implantation provide favorable clinical and angiographic outcomes in patients at high risk of restenosis and target vessel failure?
Cohort (n=112)
Does Carbostent implantation provide favorable clinical and angiographic outcomes in patients at high risk of restenosis and target vessel failure?
Carbostent implantation appears safe and effective, yielding acceptable angiographic and clinical outcomes in a high-risk patient population.
Answers are grounded in this paper and cite their sources.
May support Carbostent in high-risk restenosis; leaves open randomized confirmation of benefit.
The Carbostent is a new balloon-expandable, stainless steel, tubular stent with innovative multicellular design and unique turbostratic carbon coating. The aim of this study was to assess clinical and angiographic outcomes after Carbostent implantation in 112 patients poorly suitable for an effective treatment with stenting because of the high risk of thrombosis, late restenosis, and clinical target vessel failure. The inclusion criteria were age > 75 years, diabetes mellitus, a lesion length > 10 mm, a reference vessel diameter < 3.0 mm, an ostial location of the target lesion, and chronic total occlusion. Overall, a total of 175 stents ranging from 9 to 25 mm in length were placed in 147 lesions. There were no stenting attempt failures. The acute gain after stent implantation was 2.46 +/- 0.51 mm, and the residual stenosis 0 +/- 4%. No stent thrombosis occurred, nor myocardial infarction. The 6-month event-free survival rate was 74% +/- 5%. The 6-month angiographic follow-up showed a late loss of 0.81 +/- 0.88 mm and a binary (> or = 50%) restenosis rate of 25%. The results of this study suggest that the Carbostent may be highly effective in patients at high risk of restenosis and target vessel failure.
No takes yet. Share an insight, caveat, or question.
Antoniucci et al. (2001) conducted a cohort in High risk of restenosis and target vessel failure (n=112). Carbostent implantation was evaluated on 6-month event-free survival rate. Elective implantation of the Carbostent in patients at high risk of restenosis resulted in a 6-month event-free survival rate of 74% and a binary restenosis rate of 25%.
Synapse has enriched 10 related papers. Consider them for comparative context: