Key result
Ultrasound-guided superficial femoral artery access for coronary angiography was successfully performed in 100% of the 9 porcine models, proving to be a feasible and safe approach.
Why the study?
Detailed descriptions of coronary angiography and PCI procedures in swine contain notable differences, prompting the presentation of a feasible, reproducible protocol utilizing ultrasound-guided femoral access.
Is ultrasound-guided superficial femoral artery access feasible and safe for coronary angiography and interventions in a porcine model?
Is ultrasound-guided superficial femoral artery access feasible and safe for coronary angiography and interventions in a porcine model?
Ultrasound-guided superficial femoral artery access using AR1 and RCB catheters is a feasible and safe method for performing experimental coronary angiography and interventions in porcine models.
Background/Purpose Coronary angiography and percutaneous coronary intervention (PCI) procedural details in swine are similar to those performed to humans, since their heart and coronary anatomy closely resembles. However, only a few detailed descriptions of the procedure are available, containing notable differences. We present a feasible and reproducible protocol for percutaneous coronary interventions in porcine experimental models, utilizing ultrasound-guided femoral approach. Methods/Materials Nine female pigs were studied to explore the feasibility of superficial femoral arterial (SFA) access for coronary angiography and provisional PCI, as well as the most suitable guiding coronary catheters and angiographic projections for the above interventions. Experiments were performed under general anesthesia, using ultrasound-guided puncture of the SFA to gain arterial access. The Amplatzer AR1® catheter, and the Right Coronary Bypass® catheter were used for the selective engagement of the right and the left coronary artery respectively. Results Successful arterial access and subsequent cardiac catheterization were performed in all pigs. Only one animal required a second puncture for femoral artery access. None of the 9 animals presented any significant tachycardia or hypotensive episode. One animal developed an access site-related complication following the first catheterization procedure. During follow-up, 100% success of SFA catheterization was achieved using the same ultrasound-guided technique. Conclusions The ultrasound-guided superficial femoral artery access for coronary angiography and provisional interventions in porcine models is a quick and safe alternative to the carotid artery approach. The RCB and AR1 catheters may be the best choice for the quick and easy selective coronary engagement of the right and left ostia respectively.
No takes yet. Share an insight, caveat, or question.
Tsigkas et al. (2022) studied Healthy porcine models for experimental coronary angiography (n=9). Ultrasound-guided superficial femoral artery access was evaluated on Successful arterial access and subsequent cardiac catheterization. Ultrasound-guided superficial femoral artery access for coronary angiography was successfully performed in 100% of the 9 porcine models, proving to be a feasible and safe approach.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: