This is the authors' abstract. We don't add key points for this paper.
The accurate simulation of transient mixed flow is a crucial concern for the design and management of water-conveyance tunnels. The free-surface and pressurized flows are characterized by significant disparity in wave speed, which poses challenges in the accurate and efficient simulation of transient mixed flow. The first challenge is the numerical oscillations that frequently appear behind the filling-bore front. The second challenge is the small computational time step enforced by the Courant–Friedrichs–Lewy (CFL) stability condition that significantly limits the computational efficiency. This paper aims to address the two challenges by proposing a robust implicit finite-volume method (FVM). It employs a modified Roe solver that automatically enhances the numerical viscosity to suppress numerical oscillations and allows for the selection of computational time steps based on larger Courant numbers. A benchmark test is adopted to demonstrate the oscillation-suppression effect of the modified solver for different pressure wave speeds. Several numerical tests are conducted to validate the accuracy of the implicit FVM. In a field-scale water-conveyance tunnel, the implicit FVM produces oscillation-free and accurate results on the mixed-flow transition, while the computational time is reduced by 84% compared to the explicit FVM.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Mao et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: