The article presents an analysis of a two-phase flow in a closed pipe system, focusing on cases where the phases – air and water – do not mix. The system includes compressed air at an initial pressure higher than atmospheric and a section filled with water. Experiments were conducted to observe the movement of the water column, with the flow recorded using a high-speed camera. Characteristic shapes of both phases during the flow were selected from the recorded sequences and used to calibrate numerical simulations. By carefully adjusting the mesh parameters, good agreement between the simulation results and experimental data was achieved. This study expands on previous research by examining a system with initial air pressure higher than atmospheric. The results indicate that compressed air poses a higher risk to water networks because it can move freely along the pipe in the form of air pockets. Uncontrolled air pockets can significantly threaten the operation of sewage systems. With the growing impact of climate change and the increasing frequency of extreme weather events, the findings of this research may help to mitigate the risk of failures in stormwater drainage systems by offering better insights into the risks associated with rapid system filling.
No takes yet. Share an insight, caveat, or question.
Malesińska et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: