Fetal magnetocardiogram using DC-SQUID identified fetal QRS complexes unaffected by maternal cardiac activity, with power spectral amplitudes (120-350 fT/Hz) directly related to gestational age.
Observational (n=64)
Fetal magnetocardiogram using DC-SQUID can successfully identify fetal QRS complexes independent of maternal cardiac activity, with spectral amplitudes correlating with gestational age.
Answers are grounded in this paper and cite their sources.
Should not yet alter fetal monitoring practice; hypothesis-generating for magnetocardiography in assessing gestational age.
Power spectral analysis of fetal magnetocardiogram (FMCG) data was evaluated in 64 pregnancies, using the non-invasive one channel superconducting quantum interference device (DC-SQUID), in order to investigate the power spectral amplitude distribution in the frequency range between 2 and 3 Hz. In all cases with normal and uncomplicated pregnancies, the data from the fetal heart and specifically the QRS complexes, were identifiable and unaffected by any maternal cardiac activity and furthermore the power spectral amplitudes, which varied between 120 and 350 fT/Hz, were directly related to gestational age.
No takes yet. Share an insight, caveat, or question.
P.A. ANNINOS P. ANASTASIADIS (1999) conducted an observational in Normal and uncomplicated pregnancies (n=64). Fetal magnetocardiogram (FMCG) using DC-SQUID was evaluated on Power spectral amplitude distribution in the frequency range between 2 and 3 Hz. Fetal magnetocardiogram using DC-SQUID identified fetal QRS complexes unaffected by maternal cardiac activity, with power spectral amplitudes (120-350 fT/Hz) directly related to gestational age.