Key result
Among surface ECG markers, the Tp-Te/QT ratio demonstrated excellent diagnostic performance for predicting a premature ventricular contraction burden greater than 1% (AUC 0.9388).
Why the study?
Holter monitoring to detect high premature ventricular contraction burden is not always feasible in resource-limited settings, prompting evaluation of surface ECG repolarization markers as accessible surrogates.
Do surface ECG-derived repolarization markers correlate with and predict higher premature ventricular contraction (PVC) burden in adult patients presenting with palpitations?
Cross-Sectional (n=87)
No
Do surface ECG-derived repolarization markers correlate with and predict higher premature ventricular contraction (PVC) burden in adult patients presenting with palpitations?
Effect estimate: AUC 0.9388 (95% CI 0.86-1.00)
p-value: p=<0.0001
Surface ECG markers of ventricular repolarization, particularly the Tp-Te/QT ratio and Tp-Te interval, can serve as accessible, non-invasive surrogate indicators to identify patients with palpitations at risk of higher PVC burden who warrant further Holter monitoring.
ECG repolarization markers correlate with PVC burden; supports validation as potential Holter surrogates but leaves clinical adoption open.
BACKGROUND: Premature ventricular contractions (PVCs), often presenting as palpitations, are common in cardiology outpatient settings. While a high PVC burden is linked to adverse cardiac outcomes, its detection typically requires 24-hour Holter monitoring - an investigation not always feasible in resource-limited settings. Electrocardiographic (ECG) markers of ventricular repolarization, represented by T-wave abnormalities, such as Tp-Te interval, Tp-Te/QT ratio, and QTc dispersion, may serve as accessible surrogate indicators of PVC burden. OBJECTIVE: To evaluate the correlation between surface ECG-derived repolarization markers and PVC burden and determine which parameters best predict higher PVC burden in patients presenting with palpitations. METHODOLOGY: A total of 87 adult patients with palpitations referred to a tertiary care cardiology clinic in Northeast India underwent 12-lead ECG and 24-hour Holter monitoring. Patients were stratified into two groups based on PVC burden (<1% vs. >1%). ECG parameters, including T-wave axis angle, frontal QRS-T (fQRS-T) angle, Tp-Te interval, Tp-Te dispersion, Tp-Te/QT ratio, and QTc dispersion, were compared. Statistical analysis included Welch's t-test and Spearman's correlation. RESULTS: < 0.05). No significant correlation was observed with T-wave axis or fQRS-T angle. CONCLUSIONS: Among surface ECG markers studied, Tp-Te interval, Tp-Te/QT ratio, and QTc dispersion showed the strongest correlation with PVC burden in patients presenting with palpitations. These accessible and non-invasive markers may help identify patients at risk of higher PVC loads who may benefit from further evaluation, especially in settings where Holter monitoring is limited.
No takes yet. Share an insight, caveat, or question.
Bharadwaj et al. (2025) conducted a cross-sectional in Palpitations (n=87). Surface ECG-derived repolarization markers (Tp-Te/QT ratio) vs. Patients with PVC burden <1% was evaluated on Diagnostic performance for predicting PVC burden >1% (AUC 0.9388, 95% CI 0.86-1.00, p=<0.0001). Among surface ECG markers, the Tp-Te/QT ratio demonstrated excellent diagnostic performance for predicting a premature ventricular contraction burden greater than 1% (AUC 0.9388).