Key result
Bazett's formula showed a significant change in mean QTc between atrial fibrillation and sinus rhythm (421.5 vs 446.1; p<0.001), making it the most imprecise formula for QTc estimation in AF.
Why the study?
Atrial fibrillation is associated with elevated heart rate and beat-to-beat variation, leaving open which formula and method are best to determine QTc in AF compared to restored sinus rhythm.
Which QTc correction formula provides the best correlation between atrial fibrillation and restored sinus rhythm after electrical cardioversion?
Observational (n=50)
Which QTc correction formula provides the best correlation between atrial fibrillation and restored sinus rhythm after electrical cardioversion?
Absolute Event Rate: 421.5% vs 446.1%
p-value: p=<0.001
Bazett's formula is imprecise for estimating QTc during atrial fibrillation, whereas Framingham, Fridericia, and Hodges formulas provide more consistent values compared to sinus rhythm.
Suggests caution with Bazett's QTc in AF; leaves optimal formula open for validation.
BACKGROUND: QT interval varies with the heart rate (HR), so a correction in QT calculation is needed (QTc). Atrial fibrillation (AF) is associated with elevated HR and beat-to-beat variation. AIM: To find best correlation between QTc in atrial fibrillation (AF) versus restored sinus rhytm (SR) after electrical cardioversion (ECV) (primary end point) and to determine which correction formula and method are the best to determine QTc in AF (secondary end point). METHODS: During a 3-month period, we considered patients who underwent 12-lead ECG recording and received an AF diagnosis with indication for ECV. Exclusion criteria were as follows: QRS duration >120 ms, therapy with QT-prolonging drugs, a rate control strategy and a nonelectrical cardioversion. The QT interval was corrected using Bazzett's, Framingham, Fridericia and Hodges formulas during the last ECG during AF and the first one immediately after ECV. QTc mean was calculated as mQTc (average of 10 QTc calculated beat per beat) and as QTcM (QTc calculated from the average of 10 raw QT and RR for each beat). RESULTS: Fifty consecutive patients were enrolled in the study. Bazett's formula showed a significant change in mean QTc value between the two rhythms (421.5 ± 33.9 vs. 446.1 ± 31.9; p < 0.001 for mQTc and 420.9 ± 34.1 vs. 441.8 ± 30.9; p = 0.003 for QTcM). On the contrary, in patients with SR, QTc assessed by the Framingham, Fridericia, and Hodges formulas was similar to that in AF. Furthermore, good correlations between mQTc and QTcM are present for each formula, even in AF or SR. CONCLUSIONS: During AF, Bazzett's formula, seems to be the most imprecise in QTc estimation.
No takes yet. Share an insight, caveat, or question.
Luzza et al. (2023) conducted an observational in Atrial fibrillation (n=50). Atrial fibrillation vs. Restored sinus rhythm was evaluated on Correlation between QTc in atrial fibrillation versus restored sinus rhythm after electrical cardioversion (p=<0.001). Bazett's formula showed a significant change in mean QTc between atrial fibrillation and sinus rhythm (421.5 vs 446.1; p<0.001), making it the most imprecise formula for QTc estimation in AF.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: