Key result
Elevated glycated hemoglobin within the normal range is significantly associated with an increased risk of a restrictive spirometric pattern in a healthy, non-diabetic population (OR 3.772).
Why the study?
Is elevated HbA1c within the normal, non-diabetic range associated with deficits in lung function and restrictive spirometric patterns in healthy adults?
Cross-Sectional (n=3,670)
Yes
Is elevated HbA1c within the normal, non-diabetic range associated with deficits in lung function and restrictive spirometric patterns in healthy adults?
Odds Ratio: 3.772 (95% CI 1.234–11.53)
Elevated HbA1c levels within the normal, non-diabetic range are significantly associated with a restrictive lung pattern in healthy adults.
Glycated hemoglobin (HbA1c) is an important diagnostic indicator of diabetes mellitus, and some authors have argued that it is related to impaired lung function in the diabetic population. However, there was rare study for association between lung function and HbA1c in the non-diabetic population. We investigated whether HbA1c below the diagnostic threshold is related to deficits in lung function. We analyzed biochemical and spirometry data from a nation-wide, population-based, case-control study (the KNHANES IV and V). Eligible as cases were all native Koreans aged 40 years or more with no medical illness. A total of 3670 participants were divided into 4 groups according to HbA1c (%) as follows: Group I (n = 842), ≥ 4.0 and ≤ 5.3; Group II (n = 833), > 5.3 and ≤ 5.5; Group III (n = 898), > 5.5 and ≤ 5.7; and Group IV (n = 1097), > 5.7 and ≤ 6.4. Group I had the greatest forced vital capacity (FVC, 96.3 ± 0.5% pred, P < 0.0001), forced expiratory volume per second (FEV1, 93.8 ± 0.5% pred, P < 0.0001) and FEV1/FVC (0.792 ± 0.003, P < 0.0001) compared with the other groups. Linear regression showed that HbA1c was closely related to FVC (β = -6.972154, P < 0.0001) and FEV1 (β = -5.591589, P < 0.0001), but not to FEV1/FVC. Logistic regression analysis revealed a significant association between HbA1c and a restrictive spirometric pattern (FVC < 80% pred., FEV1/FVC ≥ 0.70; OR = 3.772, 95% CI = 1.234-11.53), indicating that elevated HbA1c is closely associated with lung impairment in the non-diabetic population. In the healthy population, relatively high HbA1c level is associated with decrements of FVC and FEV1 and may be a reliable predictor of poor lung function, especially the restrictive pattern.
No takes yet. Share an insight, caveat, or question.
Oh et al. (2015) conducted a cross-sectional in Healthy, non-diabetic general population (n=3,670). Elevated normal-range glycated hemoglobin (HbA1c) vs. Lower normal-range HbA1c was evaluated on Restrictive spirometric pattern (FVC < 80% pred., FEV1/FVC ≥ 0.70) (OR 3.772, 95% CI 1.234-11.53). Elevated glycated hemoglobin within the normal range is significantly associated with an increased risk of a restrictive spirometric pattern in a healthy, non-diabetic population (OR 3.772).