Key result
A Parzen window supervised statistical classifier model achieved 78.7% accuracy (κ = 0.67) in classifying the signal quality of single-lead ECG recordings from telehealth environments.
Effect estimate: κ = 0.67
An automated algorithm can accurately assess the quality of single-lead ECG recordings from unsupervised telehealth environments, performing similarly to expert human annotators.
May enable automated ECG quality checks in telehealth; hypothesis-generating pending prospective validation.
The use of telehealth paradigms for the remote management of patients suffering from chronic conditions has become more commonplace with the advancement of Internet connectivity and enterprise software systems. To facilitate clinicians in managing large numbers of telehealth patients, and in digesting the vast array of data returned from the remote monitoring environment, decision support systems in various guises are often utilized. The success of decision support systems in interpreting patient conditions from physiological data is dependent largely on the quality of these recorded data. This paper outlines an algorithm to determine the quality of single-lead electrocardiogram (ECG) recordings obtained from telehealth patients. Three hundred short ECG recordings were manually annotated to identify movement artifact, QRS locations and signal quality (discrete quality levels) by a panel of three experts, who then reconciled the annotation as a group to resolve any discrepancies. After applying a published algorithm to remove gross movement artifact, the proposed method was then applied to estimate the remaining ECG signal quality, using a Parzen window supervised statistical classifier model. The three-class classifier model, using a number of time-domain features and evaluated using cross validation, gave an accuracy in classifying signal quality of 78.7% (κ = 0.67) when using fully automated preprocessing algorithms to remove gross motion artifact and detect QRS locations. This is a similar level of accuracy to the reported human inter-scorer agreement when generating the gold standard annotation (accuracy = 70-89.3%, κ = 0.54-0.84). These results indicate that the assessment of the quality of single-lead ECG recordings, acquired in unsupervised telehealth environments, is entirely feasible and may help to promote the acceptance and utility of future decision support systems for remotely managing chronic disease conditions.
No takes yet. Share an insight, caveat, or question.
Redmond et al. (2012) studied chronic conditions (n=300). Parzen window supervised statistical classifier model vs. human inter-scorer agreement was evaluated on accuracy in classifying signal quality (κ = 0.67). A Parzen window supervised statistical classifier model achieved 78.7% accuracy (κ = 0.67) in classifying the signal quality of single-lead ECG recordings from telehealth environments.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: