Key result
Laser assistance was required more often for noninfected leads and those with pocket infection/erosion compared to septic leads.
Why the study?
Does the indication for lead extraction (infectious vs noninfectious) predict the need for laser assistance in patients with chronically implanted endocardial leads?
Cohort (n=283)
Does the indication for lead extraction (infectious vs noninfectious) predict the need for laser assistance in patients with chronically implanted endocardial leads?
Laser assistance is frequently required for extracting noninfected leads and those with local pocket infection, but rarely needed for leads associated with systemic sepsis.
Answers are grounded in this paper and cite their sources.
Indication for extraction may predict laser sheath needs; this Level 3 cohort leaves open prospective validation before guiding tool selection.
BACKGROUND: Powered sheaths, including Excimer laser sheaths, were introduced for the removal of transvenous pacing and defibrillator leads. The purpose of this study was to develop an algorithm to better predict which patients are likely to benefit from these devices. METHODS: We reviewed 283 consecutive patients in whom a total of 500 leads (302 pacing and 198 defibrillator leads) were extracted over a 5-year period at our operative facilities. Laser assist was utilized whenever moderate traction failed. RESULTS: In 128 patients, 203 leads were removed for noninfectious indication. In 155 patients, 297 leads for infectious indications, including sepsis 22% (111), pocket infection 23% (115), and erosion 14% (71). Laser assistance was required for 6%+/- 5% (+/- 95% confidence interval) of septic leads, 51%+/- 7% of leads associated with erosion or pocket infection and 60%+/- 7% of noninfected leads (P = 0.001). Laser assistance was necessary more often for leads implanted >12 months (53%+/- 5%) than 12 months or less (6%+/- 5%) (P = 0.001) and for ventricular (52%+/- 6%) compared to atrial (35%+/- 7%) leads (P = 0.001). CONCLUSIONS: Chronically implanted leads (>12 months), especially noninfected leads and leads associated with erosion or pocket infection, should be referred for extraction with powered sheaths to ensure successful removal. However, leads that are associated with systemic sepsis can generally be removed without powered sheaths.
No takes yet. Share an insight, caveat, or question.
Gaynor et al. (2006) conducted a cohort in Chronically implanted endocardial leads requiring extraction (n=283). Noninfectious indications or pocket infection/erosion vs. Systemic sepsis was evaluated on Requirement for laser assistance during extraction (p=0.001). Laser assistance was required more often for noninfected leads and those with pocket infection/erosion compared to septic leads.
Synapse has enriched 10 related papers. Consider them for comparative context: