Answers are grounded in this paper and cite their sources.
This paper studies a particular single-stage power-factor-correction (PFC) switching regulator employing a discontinuous-conduction-mode (DCM) boost-input cell and a continuous-current-mode (CCM) forward output cell. Although this single-stage PFC regulator can provide a reasonably high power factor when its PFC stage is operating in discontinuous mode, substantial reduction in line-current harmonics is possible by applying a suitable frequency-modulation scheme. This paper derives a frequency-modulation scheme and proposes a practical implementation using a simple translinear analog circuit. A quantitative analysis on the total harmonic distortion (THD) of the line current when the circuit is subject to a limited range of frequency variations is presented along with some considerations for practical design. Experimental data obtained from a prototype confirms the effectiveness of the proposed frequency-modulation scheme. The proposed analog translinear circuit allows custom integrated circuit implementation, making it a viable low-cost solution to the elimination of line-current harmonics in switching regulators.
No takes yet. Share an insight, caveat, or question.
Chow et al. (1998) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: