Answers are grounded in this paper and cite their sources.
Reduced graphene oxide (rGO) and Au nanodot (AuND, ∼1.5 nm) modified rGO, referred to as AuNDs-rGO, synthesized by a simple photochemical reduction method, are used for electrochemical biosensors. Our experimental results showed that the glucose oxidase (GOX)/rGO/Nafion/glassy carbon electrode (GCE) exhibits a linear range from 0.03 to 6.28 mM and a detection limit of 0.03 mM at a signal-to-noise (S/N) ratio of 3 for the amperometric sensing of glucose, while the GOX/AuNDs-rGO/Nafion/GCE shows a wider linear range from 0.02 to 8.82 mM and a lower detection limit of 0.02 mM. This difference may arise from the high catalytic activity of the AuNDs. Our studies demonstrate that the composites of rGO/Nafion and AuNDs-rGO/Nafion might offer a new class of electrode materials, and provide a promising platform for biosensing applications.
No takes yet. Share an insight, caveat, or question.
Mei et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: