This is the authors' abstract. We don't add key points for this paper.
Wearable devices can suppress or reduce hand tremor motion associated with neurological disorders such as Parkinson's disease. Tendon-driven transmission systems have been proposed as a way to decrease the size and weight of these devices; however, they have complex control system requirements due to their substantially nonlinear behavior. To address this issue, this study focused on the development of a comprehensive kinematic model of a wearable tremor suppression glove that more accurately calculates the tendon displacement during hand motion. The novelty lies in the identification of the threshold bending angle for each joint at which the driven tendon touches the arc of the joint. The derived kinematic model of the glove was verified by both simulation and benchtop experiments, and the proposed model was validated during single-joint and multijoint hand movements. The kinematic model shows a mean 2-D correlation coefficient of 0.96±0.01 with the experimental data. Compared to the Euclidean norm model presented in the literature, it presents an average 83% improvement (a 4%–96% reduction in root mean square errors depending on the joint), which is most significant for increasing tendon displacements.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Daemi et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: