Key result
Lower baseline aortic valve peak pressure gradient (OR 0.97) and the absence of moderate-to-severe aortic regurgitation (OR 0.65) were independent predictors of ViV-TAVI procedural success.
Why the study?
Data were lacking on the determinants of ViV-TAVI procedural success in patients with degenerated surgical valves.
Observational (n=186)
No
Lower baseline aortic valve peak pressure gradient and the absence of moderate-to-severe aortic regurgitation are independent predictors of procedural success in patients undergoing ViV-TAVI for degenerated surgical valves.
Background: Valve-in-Valve transcatheter aortic valve implantation (ViV-TAVI) is a growing alternative for redo-surgery in patients with degenerated surgical valves. To our knowledge, data are lacking on the determinants on ViV-TAVI procedural success in patients with degenerated surgical valves. Methods: All consecutive patients undergoing ViV-TAVI for degenerated surgical valves at the Cleveland Clinic were analyzed. Data were extracted from our patient registry on baseline patient characteristics, echocardiographic parameters, and procedural details. To identify possible predictors of ViV-TAVI procedural success, we employed a multivariate logistic regression model. Results: A total of 186 patients who underwent ViV-TAVI were analyzed, with procedural success (VARC-2 device success and absence of periprocedural MACCE) reported in 165 (88.7%) patients. Patients with successful ViV-TAVI were significantly younger and had more frequent utilization of the transfemoral access than those with failed procedure. Other baseline and procedural characteristics were comparable between both groups. In terms of echocardiographic parameters, the procedural success group had a significantly lower AV peak pressure gradient (62.1 ± 24.7 vs. 74.1 ± 34.6 mmHg; p = 0.04) and lower incidence of moderate-to-severe aortic regurgitation [AR] (30.4 vs. 55%; p = 0.04). However, no significant differences between both groups were noted in terms of AV mean pressure gradient and left ventricular measurements. In multivariate analysis, lower AV peak pressure gradient (OR = 0.97, 95% CI: 0.95–0.99) and absence of moderate-to-severe AR (OR = 0.65, 95% CI: 0.44–0.95) at baseline emerged as independent predictors of ViV-TAVI procedural success. Conclusion: Valve-in-Valve TAVI for degenerated surgical valves is a feasible approach with high success rates, especially in those with lower AV peak pressure gradient and absence of moderate-to-severe AR. Studies with larger sample size and longer follow-up are required to further characterize the predictors of ViV-TAVI success and other clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Abushouk et al. (2021) conducted an observational in Degenerated surgical valves (n=186). Lower AV peak pressure gradient vs. Higher AV peak pressure gradient was evaluated on ViV-TAVI procedural success (VARC-2 device success and absence of periprocedural MACCE) (OR 0.97, 95% CI 0.95-0.99, p=0.04). Lower baseline aortic valve peak pressure gradient (OR 0.97) and the absence of moderate-to-severe aortic regurgitation (OR 0.65) were independent predictors of ViV-TAVI procedural success.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: