Key result
18F-FBPA PET/CT demonstrated significantly superior diagnostic ability for distinguishing malignant tumors from benign lesions compared to 18F-FDG PET/CT (AUC 0.834 vs. 0.547, p < 0.001).
Why the study?
The study was conducted to evaluate the diagnostic ability of 18F-FBPA PET/CT for malignant tumors compared with 18F-FDG PET/CT and pathological diagnoses.
Does 18F-FBPA PET/CT improve the diagnostic accuracy for differentiating malignant tumors from benign lesions compared to 18F-FDG PET/CT?
Cross-Sectional (n=82)
Does 18F-FBPA PET/CT improve the diagnostic accuracy for differentiating malignant tumors from benign lesions compared to 18F-FDG PET/CT?
Answers are grounded in this paper and cite their sources.
18F-FBPA PET/CT demonstrates superior diagnostic accuracy over 18F-FDG PET/CT for differentiating malignant tumors from benign lesions, potentially reducing false-positive diagnoses.
Background The goal of the study was to evaluate the diagnostic ability of 18F-FBPA PET/CT for malignant tumors. Findings from 18F-FBPA and 18F-FDG PET/CT were compared with pathological diagnoses in patients with malignant tumors or benign lesions. Methods A total of 82 patients (45 males, 37 females; median age, 63 years; age range, 20–89 years) with various types of malignant tumors or benign lesions, such as inflammation and granulomas, were examined by 18F-FDG and 18F-FBPA PET/CT. Tumor uptake of FDG or FBPA was quantified using the maximum standardized uptake value (SUVmax). The final diagnosis was confirmed by cytopathology or histopathological findings of the specimen after biopsy or surgery. A ROC curve was constructed from the SUVmax values of each PET image, and the area under the curve (AUC) and cutoff values were calculated. Results The SUVmax for 18F-FDG PET/CT did not differ significantly for malignant tumors and benign lesions (10.9 ± 6.3 vs. 9.1 ± 2.7 P = 0.62), whereas SUVmax for 18F-FBPA PET/CT was significantly higher for malignant tumors (5.1 ± 3.0 vs. 2.9 ± 0.6, P < 0.001). The best SUVmax cutoffs for distinguishing malignant tumors from benign lesions were 11.16 for 18F-FDG PET/CT (sensitivity 0.909, specificity 0.390) and 3.24 for 18F-FBPA PET/CT (sensitivity 0.818, specificity 0.753). ROC analysis showed significantly different AUC values for 18F-FDG and 18F-FBPA PET/CT (0.547 vs. 0.834, p < 0.001). Conclusion 18F-FBPA PET/CT showed superior diagnostic ability over 18F-FDG PET/CT in differential diagnosis of malignant tumors and benign lesions. The results of this study suggest that 18F-FBPA PET/CT diagnosis may reduce false-positive 18F-FDG PET/CT diagnoses.
No takes yet. Share an insight, caveat, or question.
Isohashi et al. (2022) conducted a cross-sectional in Malignant tumors and benign lesions (n=82). 18F-FBPA PET/CT vs. 18F-FDG PET/CT was evaluated on Area under the ROC curve (AUC) for distinguishing malignant tumors from benign lesions (p=<0.001). 18F-FBPA PET/CT demonstrated significantly superior diagnostic ability for distinguishing malignant tumors from benign lesions compared to 18F-FDG PET/CT (AUC 0.834 vs. 0.547, p < 0.001).