Answers are grounded in this paper and cite their sources.
Accurate inline layer height measurement in three-dimensional concrete printing (3DCP) remains challenging because optical and acoustic sensors are affected by near-nozzle geometry, variations in surface condition, temperature effects on acoustic propagation, and process-induced disturbances. This study develops and validates a cross-modal calibration framework for heterogeneous optical and acoustic distance sensors used for inline layer height measurement in 3DCP. The framework integrates a stereo depth camera, a time-of-flight (ToF) sensor, and an ultrasonic transducer, and combines region-of-interest processing, geometric correction, temperature compensation for ultrasonic measurements, and least-squares calibration. Beyond integrating established calibration techniques, the specific methodological contribution is a sensor-aware composite reliability weighting scheme that combines measurement stability, sensor-native validity, and range-dependent reliability to harmonize heterogeneous optical and acoustic measurements within a common layer-height reference frame. The proposed workflow addresses sensor-specific sources of systematic bias, random error, and range-dependent reliability, thereby providing a consistent reference-based measurement framework for near-nozzle monitoring. Validation was performed using reference gauges and in-process experiments on freshly extruded and hardened concrete layers. Across the investigated cases, calibration substantially reduced measurement error, with the D405 depth camera achieving sub-millimeter consistency and the ToF and ultrasonic sensors improving to millimeter-level agreement with the reference. Dynamic validation against an independent laser displacement reference confirmed that the calibrated sensors maintained improved agreement during active extrusion. The validation was limited to straight-path extrusion over 1 m, two representative concrete surface states, and nominal layer heights of 20 mm and 40 mm. The results demonstrate that the proposed calibration workflow improves the consistency, repeatability, and comparability of heterogeneous distance measurements within the investigated 3DCP conditions, while broader validation under complex geometries, extended print durations, and controlled disturbance scenarios remains future work.
No takes yet. Share an insight, caveat, or question.
Rahimi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: