Key result
The MRX PT DOAC assay demonstrated a sensitivity of 1.00 for detecting apixaban and rivaroxaban concentrations known to cause analytical interference in thrombophilia testing.
Why the study?
DOACs can interfere with coagulation analyses, leading to erroneous results that threaten patient safety, prompting evaluation of the MRX PT DOAC test for detecting this interference.
Does the MRX PT DOAC screening method accurately detect DOAC interference in thrombophilia analyses in patient plasma samples?
Observational (n=612)
Yes
Does the MRX PT DOAC screening method accurately detect DOAC interference in thrombophilia analyses in patient plasma samples?
The MRX PT DOAC test is a highly sensitive screening tool for detecting apixaban and rivaroxaban interference in thrombophilia analyses, potentially improving diagnostic accuracy.
Answers are grounded in this paper and cite their sources.
May support lab screening to flag DOAC interference in thrombophilia testing; leaves open need for larger validation before routine use.
BACKGROUND: Direct oral anticoagulants (DOACs) can interfere with coagulation analyses, causing erroneous results such as false-positive lupus anticoagulant and false-normal antithrombin, threatening patient safety when overlooked. A test using a prothrombin time quotient method to detect DOAC presence in plasma samples is now commercially available, the MRX PT DOAC, with the result expressed as Clot Time Ratio (CTR). OBJECTIVES: Evaluate the ability of MRX PT DOAC to identify interfering apixaban or rivaroxaban concentrations, identify non-interfering or interfering patient samples, and detect whether a patient is on DOAC treatment. METHODS: An MRX PT DOAC reference interval was established, and MRX PT DOAC results related to FXa inhibitor concentrations. MRX PT DOAC patient plasma results were related to indications of analytical interference with lupus anticoagulant and antithrombin analyses and with the patients' anticoagulant drug use, according to medical records. RESULTS: The MRX PT DOAC CTR reference interval was 0.98-1.38. MRX PT DOAC apixaban and rivaroxaban interference detection sensitivity was 1.00 (0.96 - 1.0). For subgroups from 315 patient plasma samples, the negative predictive values estimates were 0.84 or above (95% confidence interval minimum 0.64) for excluding analysis interference with the lupus anticoagulant and antithrombin analyses and for excluding DOAC treatment as per medical records. All 9 interference-indicating DOAC samples were identified for the lupus anticoagulant analyses, 5 out of 11 for antithrombin. CONCLUSIONS: The MRX PT DOAC is a potential screening tool for interference. Confirming results in a larger DOAC patient group and further investigating the antithrombin interference detection uncertainty is important.
No takes yet. Share an insight, caveat, or question.
Arbring et al. (2025) conducted an observational in Thrombophilia testing and DOAC treatment (n=612). MRX PT DOAC assay vs. Standard laboratory methods and DOAC-Stop was evaluated on Sensitivity for detecting apixaban and rivaroxaban interference (Sensitivity 1.00, 95% CI 0.96-1.0). The MRX PT DOAC assay demonstrated a sensitivity of 1.00 for detecting apixaban and rivaroxaban concentrations known to cause analytical interference in thrombophilia testing.
Synapse has enriched 10 related papers. Consider them for comparative context: