Key result
A multiscale spatiotemporal feature extraction method based on a Convolutional Neural Network achieved 99.51% accuracy for MI detection and a macro-F1 of 99.14% for MI localization.
Why the study?
Automatic diagnosis of MI based on 12-lead ECG requires considering both multiresolution time-series waveform changes and spatial correlation between leads.
Does a multiscale spatiotemporal feature extraction method based on CNN improve the accuracy of MI detection and localization from 12-lead ECGs?
Does a multiscale spatiotemporal feature extraction method based on CNN improve the accuracy of MI detection and localization from 12-lead ECGs?
A novel CNN-based model using multiscale spatiotemporal feature extraction from 12-lead ECGs achieves high accuracy for automated myocardial infarction detection and localization.
Proposed CNN method may support automated MI detection from ECG; leaves open clinical utility pending validation.
Electrocardiogram (ECG) is widely used in Myocardial infarction (MI) diagnosis. The automatic diagnosis of MI based on the 12-lead ECG needs to consider not only the waveform change features in multi-resolution time series, but also the spatial correlation information between the leads. To this end, this work proposed multiscale spatiotemporal feature extraction method based on Convolutional neural network (CNN) for MI automatic diagnosis. First, the 12-lead ECG is first transformed into an ECG image through wavelet decomposition and 3-dimensional space reconstruction. The MI-CNN model is then constructed to identify MI using 41368 ECG images. Finally, we develop the LL-CNN model, which is utilized only after the ECG signal is identified as an MI event by the MI-CNN model, to localize MI by employing transfer learning to overcome the limited data problem. The proposed method has achieved an accuracy of 99.51% on MI detection, and a macro-F1 of 99.14% on MI localization. Moreover, the features visualization shows that U-wave has significant diagnostic value for MI. The proposed method significantly improves the performance of MI detection and localization compared with other methods. It is promising to be used for MI monitoring and diagnosis.
No takes yet. Share an insight, caveat, or question.
Jikui et al. (2021) studied Myocardial infarction (n=41,368). Convolutional neural network (MI-CNN and LL-CNN models) vs. Other methods was evaluated on MI detection accuracy and MI localization macro-F1. A multiscale spatiotemporal feature extraction method based on a Convolutional Neural Network achieved 99.51% accuracy for MI detection and a macro-F1 of 99.14% for MI localization.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: