Key result
Near-infrared spectroscopy with vascular occlusion test demonstrated good to excellent relative reliability in younger (ICCs 0.74-0.86) and middle-aged/older women (ICCs 0.51-0.87).
Why the study?
The study assessed whether near-infrared spectroscopy with vascular occlusion test (NIRS-VOT) can reliably measure skeletal muscle metabolic and microvascular function in women.
Does the near-infrared spectroscopy with vascular occlusion test (NIRS-VOT) reliably measure skeletal muscle metabolic and microvascular function in women across different age groups?
Cross-Sectional
Does the near-infrared spectroscopy with vascular occlusion test (NIRS-VOT) reliably measure skeletal muscle metabolic and microvascular function in women across different age groups?
NIRS-VOT is a reliable, non-invasive technique for assessing skeletal muscle metabolism and microvascular function in women, revealing age-related declines in these parameters.
Supports NIRS-VOT reliability in women across ages; leaves open clinical adoption pending prospective validation.
NEW FINDINGS: What is the central question of this study? Can the near-infrared spectroscopy with vascular occlusion test (NIRS-VOT) reliably measure skeletal muscle metabolic and microvascular function in women? What is the main finding and its importance? The NIRS-VOT can be used as a reliable technique for the assessment of skeletal muscle metabolism and microvascular function in women, with reliability being generally greater in younger women. These findings have important implications for the planning and development of future studies employing the NIRS-VOT in women, and provide insights into the effects of age on these parameters in women specifically. ABSTRACT: (intraclass correlation coefficient (ICC) = 0.37; coefficient of variation (CV) = 31%), time to max tissue saturation (ICC = 0.21), and ischaemic index (ICC = 0.37) for MAOW, all of the NIRS variables demonstrated good to excellent relative reliability for the YW (ICCs = 0.74-0.86) and the MAOW (ICCs = 0.51-0.87), with CVs of 2-21% and 2-22%, respectively. The occlusion slope was significantly lower, indicating accelerated deoxygenation, while maximum tissue saturation, reperfusion magnitude, and ischaemic index were significantly higher in YW versus MAOW. No other group differences were found. In conclusion, our data support the use of the NIRS-VOT as a simple, reliable, non-invasive technique for the assessment of peripheral skeletal muscle metabolism and microvascular function in women, with the reliability being generally greater in YW versus MAOW. Further, our data suggest that ageing is associated with lower skeletal muscle metabolism and microvascular hyperaemic responsiveness in women.
No takes yet. Share an insight, caveat, or question.
Rogers et al. (2022) reported a cross-sectional. Near-infrared spectroscopy with vascular occlusion test (NIRS-VOT) was evaluated on Relative reliability of NIRS variables. Near-infrared spectroscopy with vascular occlusion test demonstrated good to excellent relative reliability in younger (ICCs 0.74-0.86) and middle-aged/older women (ICCs 0.51-0.87).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: