Key result
An unobtrusive ambient sensor system detected early signs of heart failure decompensation, such as increased respiration rate and decreased physical activity, weeks before hospitalization in a 91-year-old man.
Why the study?
Contactless ambient sensor systems have potential to detect clinical signs of HF decompensation to prevent deterioration and hospitalization, but data demonstrating this capability are needed.
Does an ambient sensor system detect early signs of heart failure decompensation in a high-risk elderly patient?
Case Report (n=1)
No
Does an ambient sensor system detect early signs of heart failure decompensation in a high-risk elderly patient?
Contactless ambient sensor systems can detect early physiological and behavioral changes that precede clinical heart failure decompensation, potentially enabling early intervention.
Ambient sensors may aid remote HF monitoring; case report leaves open need for prospective validation before practice change.
Home monitoring systems are increasingly used to monitor seniors in their apartments for detection of emergency situations. More recently, multimodal ambient sensor systems are also used to monitor digital biomarkers to detect clinically relevant health problems over longer time periods. Clinical signs of HF decompensation including increase of heart rate and respiration rate, decreased physical activity, reduced gait speed, increasing toilet use at night and deterioration of sleep quality have a great potential to be detected by non-intrusive contactless ambient sensor systems and negative changes of these parameters may be used to prevent further deterioration and hospitalization for HF decompensation. This is to our knowledge the first report about the potential of an affordable, contactless, and unobtrusive ambient sensor system for the detection of early signs of HF decompensation based on data with prospective data acquisition and retrospective correlation of the data with clinical events in a 91 year old senior with a serious heart problem over 1 year. The ambient sensor system detected an increase of respiration rate, heart rate, toilet use at night, toss, and turns in bed and a decrease of physical activity weeks before the decompensation. In view of the rapidly increasing prevalence of HF and the related costs for the health care systems and the societies, the real potential of our approach should be evaluated in larger populations of HF patients.
No takes yet. Share an insight, caveat, or question.
Saner et al. (2021) conducted a case report in Heart Failure Decompensation (n=1). Ambient sensor system (PIR motion and bed sensors) was evaluated on Changes in digital biomarkers (respiration rate, heart rate, physical activity) prior to heart failure decompensation. An unobtrusive ambient sensor system detected early signs of heart failure decompensation, such as increased respiration rate and decreased physical activity, weeks before hospitalization in a 91-year-old man.