Key result
Institution of a personalized lead protocol significantly increased the proportion of dosimeters reporting radiation exposure from 73.1% to 88.7% among orthopaedic surgery residents.
Why the study?
Radiation exposure of orthopaedic residents must be accurately tracked to mitigate risk, but whether a personalized lead protocol with a monitoring officer improves exposure monitoring was unknown.
Does a personalized lead protocol improve radiation exposure monitoring compliance and readings in orthopaedic surgery residents?
Case-Control (n=15)
No
Does a personalized lead protocol improve radiation exposure monitoring compliance and readings in orthopaedic surgery residents?
Absolute Event Rate: 88.7% vs 73.1%
p-value: p=<0.001
Implementing a personalized lead protocol with a radiation safety officer significantly improves compliance and accuracy of radiation exposure monitoring among orthopaedic residents.
Personalized lead protocols may improve resident radiation monitoring compliance; leaves open whether this reduces cumulative exposure in orthopaedic training.
Background: Radiation exposure of orthopaedic residents should be accurately monitored to monitor and mitigate risk. The purpose of this study was to determine whether a personalized lead protocol (PLP) with a radiation monitoring officer would improve radiation exposure monitoring of orthopaedic surgery residents. Materials and Methods: This was a retrospective case-control study of 15 orthopaedic surgery residents monitored for radiation exposure during a 2-year period (March 2017 until February 2019). During the first 12-month period (phase 1), residents were given monthly radiation dosimeter badges and instructed to attach them daily to the communal lead aprons hanging outside the operating rooms. During the second 12-month period (phase 2), a PLP (PLP group) was instituted in which residents were given lead aprons embroidered with their individual names. A radiation safety officer was appointed who placed the badges monthly on all lead aprons and collected them at the end of the month, whereas faculty ensured residents wore their personalized lead apron. Data collected included fluoroscopy use time and radiation dosimeter readings during all orthopaedic surgeries in the study period. Results: There were 1,252 orthopaedic surgeries using fluoroscopy during phase 1 in the control group and 1,269 during phase 2 in the PLP group. The total monthly fluoroscopy exposure time for all cases averaged 190 minutes during phase 1 and 169 minutes during phase 2, with no significant difference between the groups (p < 0.45). During phase 1, 73.1% of the dosimeters reported radiation exposure, whereas during phase 2, 88.7% of the dosimeters reported radiation exposure (p < 0.001). During phase 1, the average monthly resident dosimeter exposure reading was 7.26 millirems (mrem) ± 37.07, vs. 19.00 mrem ± 51.16 during phase 2, which was significantly higher (p < 0.036). Conclusions: Institution of a PLP increased the compliance and exposure readings of radiation dosimeter badges for orthopaedic surgery residents, whereas the actual monthly fluoroscopy time did not change. Teaching hospitals should consider implementing a PLP to more accurately monitor exposure. Level of Evidence: 3.
No takes yet. Share an insight, caveat, or question.
Massey et al. (2022) conducted a case-control in Occupational radiation exposure (n=15). Personalized lead protocol vs. Communal lead aprons (no personalized protocol) was evaluated on Proportion of dosimeters reporting radiation exposure (p=<0.001). Institution of a personalized lead protocol significantly increased the proportion of dosimeters reporting radiation exposure from 73.1% to 88.7% among orthopaedic surgery residents.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: