Case report reveals arterial puncture characteristics during internal jugular vein catheterization, highlighting challenges in confirming catheter tip position.
No abstract available. Article truncated after 150 words. A 66-year-old man a with history of systolic heart failure and end-stage renal disease on hemodialysis was admitted to the intensive care unit due to cardiogenic shock requiring inotropes. As left arm fistula was clotted, left internal jugular vein triple-lumen catheter (IJC) was placed to obtain a hemodialysis access. Central line placement was performed under ultrasound guidance with no complications. A confirmatory chest x-ray revealed central venous catheter malposition; the catheter tip did not cross the midline; instead, it projected over the left lung field which was concerning for arterial puncture of the carotid artery (Figure 1). Bedside ultrasonography showed an appropriate catheter placement in the left internal jugular vein, but the final catheter tip location was unclear. The transduced pressure was low; approximately 5mmHg. A blood gas sample from the catheter was compatible with arterial blood; pH 7.42, pCO2 34, and pO2 92. Computed tomography scan of the head …