Answers are grounded in this paper and cite their sources.
Detection of the site of blockage that produces obstruction of the superior vena cava has usually been determined by venous angiography (1–3). The angiogram provides accurate information concerning alterations in circulation, but obstruction increases the risk of complications from the procedure. Also, passage of the contrast medium in high concentration through collaterals may produce a greater degree of discomfort than is usually encountered in angiographic studies. Not infrequently more than one injection has been required to produce the desired degree of visualization of the superior vena cava. An alternate method for evaluation of the superior vena cava is the technetium-99m pertechnetate (99mTc) superior vena cavogram. The use of stationary imaging devices for evaluation of vascular flow through major blood vessels has been documented by several investigators (4–8). The short half-life tracers used for these studies have produced no discomfort, morbidity, or mortality. Materials and Methods This report is based on the study of 20 patients with obstruction of the superior vena cava secondary to bronchogenic carcinoma, referred to the Radiation Therapy Department of the Ochsner Foundation Hospital or the Radiation Therapy Department of Charity Hospital, New Orleans, La., for radiation therapy. In this series one and sometimes serial 99mTc superior vena cavograms were obtained to evaluate the degree of initial obstruction and the response to irradiation. This report will consider in detail only the accuracy of 99mTc superior vena cavography for initial diagnosis. In 10 of the 20 patients venous angiography was also carried out. The angiograms were usually obtained before the 99mTc study. For the 99mTc superior vena cavogram, an Anger camera was positioned anteriorly over the superior mediastinal area, and the 4,000-hole low-energy collimator was employed. The isotope range and peak were set for 99mTc, and a 15 per cent window was used. An intravenous bolus of 10 mc of 99mTc was injected into one antecubital vein. Starting two seconds postinjection, serial camera images were obtained by pulling the Polaroid film from the recording camera at approximately two-second intervals. To permit longer evaluation of the flow patterns, a 35-mm camera positioned over the second oscilloscope with a separate interval-timing mechanism has been employed, since as many as 36 frames can be obtained with this unit. Results A normal 99mTc superior vena cavogram is shown in Figure 1, A. Figure 1, B is a series of camera images of normal venae cavae six seconds after injection. In all of the 20 patients with clinical evidence of obstruction of the superior vena cava, the 99mTc superior vena cavogram was abnormal. In all 10 patients in whom venous angiography was also performed, both the 99mTc superior vena cavogram and the venous angiogram were abnormal.
No takes yet. Share an insight, caveat, or question.
Maxfield et al. (1969) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: