Answers are grounded in this paper and cite their sources.
Time constant of decay of coupling current was measured on cable-in-conduit conductors which consist of twelve Nb3Sn strands with chrome plating. The time constant measurement was performed by observing exponential decrease of induced coupling current in conductors. The measured time constant of conductor composed of bare strands was 4.5 times larger than that of the single strand, in case that a void fraction of conductor was 30%. However, the time constant of conductor composed of strands with chrome plating of more than 2μm thickness was equal to that of the single strand. These results show that chrome plating on strands is effective for decrease of coupling losses in Nb3Sn cable-in-conduit conductors.
No takes yet. Share an insight, caveat, or question.
ANDO et al. (1987) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: