Key result
Minimally invasive sutureless aortic valve replacement was associated with significantly lower in-hospital mortality compared to conventional AVR (0.97% vs 2.43% in matched patients; p<0.0001).
Why the study?
Available evidence suggests a minimally invasive approach using sutureless bioprostheses favorably impacts outcomes in patients undergoing AVR.
Does minimally invasive sutureless aortic valve replacement reduce in-hospital mortality compared to conventional aortic valve replacement in patients undergoing AVR?
Cohort (n=2,732)
Does minimally invasive sutureless aortic valve replacement reduce in-hospital mortality compared to conventional aortic valve replacement in patients undergoing AVR?
Absolute Event Rate: 0.97% vs 2.43%
p-value: p=<0.0001
Minimally invasive sutureless AVR is associated with significantly lower in-hospital mortality compared to conventional AVR, rendering EuroSCORE II less effective for risk prediction in this cohort.
Objective. Available evidence suggests that a minimally invasive approach with the use of sutureless bioprostheses has a favorable impact on the outcome of patients undergoing aortic valve replacement (AVR). Methods. From 2010 to 2019, 2732 patients underwent conventional AVR through median sternotomy with a stented bioprosthesis (n = 2048) or minimally invasive AVR with a sutureless bioprosthesis (n = 684). Results. Using the propensity score, 206 patients in each group were matched, and the matched groups were well balanced regarding preoperative risk factors. Both unmatched and matched patients of the sutureless + minimally invasive group showed significantly shorter cross-clamp times and longer ICU stay. In-hospital mortality was the only outcome measure that was confirmed in both analyses, and was higher in the stented + conventional group (2.54% and 2.43% in unmatched and matched patients, respectively) compared with the sutureless + minimally invasive group (0.88% and 0.97% in unmatched and matched patients, respectively) (p = 0.0047 and p < 0.0001, respectively). No differences in postoperative pacemaker implantation were recorded in matched patients of both groups (n = 2 [1%] in the stented + conventional group vs. n = 4 [2%] in the sutureless + minimally invasive group; p = 0.41). The discrimination power of EuroSCORE II was not confirmed in the sutureless + minimally invasive group, yielding an area under the ROC curve of 0.568. Conclusions. Minimally invasive sutureless AVR has a favorable impact on the immediate outcome and is associated with significantly lower in-hospital mortality rates compared with conventional AVR, resulting in the absence of the discrimination power of EuroSCORE II for predicting AVR outcomes.
No takes yet. Share an insight, caveat, or question.
Santarpino et al. (2022) conducted a cohort in Aortic valve replacement (AVR) (n=2,732). Minimally invasive AVR with a sutureless bioprosthesis vs. Conventional AVR through median sternotomy with a stented bioprosthesis was evaluated on In-hospital mortality (p=<0.0001). Minimally invasive sutureless aortic valve replacement was associated with significantly lower in-hospital mortality compared to conventional AVR (0.97% vs 2.43% in matched patients; p<0.0001).