Key result
TEVAR after Type A dissection repair yields ~13% mortality alongside substantial false lumen thrombosis.
Why the study?
A residual false lumen after surgery for type A aortic dissection is associated with early and delayed complications, and while TEVAR is used to prevent these complications, the indications, methods, clinical outcomes, and aortic remodeling required investigation.
Is Thoracic Endovascular Aortic Repair (TEVAR) an effective and safe approach to promote aortic remodeling and prevent complications in patients with residual false lumen after open surgery for Type A aortic dissection?
Systematic Review (n=157)
Is Thoracic Endovascular Aortic Repair (TEVAR) an effective and safe approach to promote aortic remodeling and prevent complications in patients with residual false lumen after open surgery for Type A aortic dissection?
TEVAR after open surgery for Type A aortic dissection promotes false lumen thrombosis (65.9%) with a 12.7% mortality rate and 18.7% reintervention rate, though standardized selection criteria and randomized trials are needed.
Answers are grounded in this paper and cite their sources.
TEVAR may promote remodeling after Type A repair; leaves open efficacy, safety, and standardized indications pending randomized trials.
Introduction: A residual false lumen after treatment for Aortic Dissection type A (AD) has been associated with early complications, such as A malperfusion or rupture and mid-term or delayed complications, such as aneurysm formation or dissection expansion. Thoracic Endovascular Aortic Repair (TEVAR) is considered an effective solution by several surgical teams to prevent future complications. In this systematic review, all published data regarding the implementation of TEVAR after previous treatment for AD were collected in order to investigate indications, methods, clinical outcomes and aortic remodeling in these patients. Methods: The aim of this study was to investigate the indications, the methods and the efficacy of TEVAR usage after surgical treatment of AD. Data for this study were collected from four widely used medical databases (MEDLINE, SCIENCE DIRECT, GOOGLE SCHOLAR, OVID). All the results for each database were recorded and were analyzed with a systematic method. Techniques and clinical outcomes were investigated. Aortic remodeling was evaluated based on the following parameters in these studies: aortic diameter, true lumen diameter, false lumen diameter, false lumen thrombosis and false lumen patency. Results: The results obtained from the search among all databases comprised 1410 articles and of these articles 9 were included in the review. The majority of the studies were retrospective (seven out of nine studies), while no study was randomized. The total number of patients was 157 and 133 of them (84.7% of patients) were treated with TEVAR in zone 3 without extension below the diaphragm intraoperatively. Among 142 patients, the calculated mortality rate was 12.7% (18 of 142 patients), with 2.8% (4 of 142 patients) presenting with stroke. The percentage of patients with total or partial thrombosis combined was 65.9% (62 patients in a population of 92). The reintervention rate was 18.7%. Conclusions: TEVAR after AD surgery is an approach usually chosen in clinical practice, but the criteria of its usage are uncertain. This method is safe and enhances aortic remodeling with an acceptable reintervention rate. Definite guidelines in this field should be created in order to delineate whether TEVAR after AD surgery is beneficial as a preventive measure to aorta-related complications and to decide under which criteria this approach should be chosen.
No takes yet. Share an insight, caveat, or question.
Schizas et al. (2024) conducted a systematic review in Residual false lumen after surgical treatment for Aortic Dissection Type A (n=157). Thoracic Endovascular Aortic Repair (TEVAR) was evaluated on All-cause mortality (among 142 patients with reported clinical outcomes). Thoracic Endovascular Aortic Repair after Type A aortic dissection surgery resulted in a 12.7% mortality rate, 65.9% total or partial false lumen thrombosis, and an 18.7% reintervention rate.
Synapse has enriched 10 related papers. Consider them for comparative context: