We tested the antimicrobial activity of orthophthalaldehyde (OPA) against 21 strains (16 species) of pathogenic microorganisms that cause hospital-associated infections. Changes in hepatitis B surface antigen (HBs-Ag) resulting from the addition of OPA to HBs-Ag-positive serum were measured using a radioimmunoassay. We also examined the effect of immersing medical instruments in OPA (0.55%) for 168 h at room temperature. OPA (0.5%, 0.37% and 0.25%) killed 11 strains of vegetative bacteria within 15 s, and it killed the test micro-organisms faster than 3.0% glutaraldehyde (GTA). Incubation with OPA or GTA caused levels of HBs-Ag to fall below a cut-off value within 30 s. OPA did not adversely affect instruments made from various materials. OPA demonstrated more effective antimicrobial activity than GTA against a range of microorganisms. We conclude that OPA should replace GTA as the first-choice high-level disinfectant for endoscopes, considering its antimicrobial efficacy and low inhalation toxicity.
No takes yet. Share an insight, caveat, or question.
Akamatsu et al. (2005) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: