Answers are grounded in this paper and cite their sources.
A method is described for the qualitative and semi-quantitative simultaneous determination of both non-macrocyclic and macrocyclic trichothecene biotoxins from samples derived from indoor environments. The method includes extraction, sample pre-treatment and reversed-phase HPLC separation followed by tandem mass spectrometric identification and quantification using electrospray ionization on a quadrupole ion trap mass analyser. Aqueous methanol was used in the initial extraction and solvent partitioning and solid-phase extraction in the purification of samples. The HPLC separation was run on-line with electrospray ionization MS-MS detection. The detection limits and recoveries of the procedure varied from 1 to 1000 pg and from 31 to 92%, respectively. As the method includes few and not very labour intensive sample treatment steps, it should allow for a high throughput of samples with good prospects of automation.
No takes yet. Share an insight, caveat, or question.
Tuomi et al. (1998) studied this question.