This is the authors' abstract. We don't add key points for this paper.
In this study, a preload monitoring method using impedance signatures obtained from a piezoelectric-based smart interface is presented for bolted girder connections. Firstly, the background theory of the piezoelectric-based smart interface and its implementation into health monitoring of bolted connections are outlined. A simplified electro-mechanical (EM) impedance model of a smart interface-embedded bolted connection system is formulated to interpret mechanistic understanding of EM impedance signatures under the effect of bolt preload. Secondly, finite element modeling of a bolted connection is carried out to show the numerical feasibility of the presented method and to predetermine the sensitive frequency band of impedance signatures. Finally, impedance measurements are conducted on a lab-scaled bolted girder connection to verify the predetermined sensitive frequency range and to assess the bolt preload changes in the test structure.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Huynh et al. (2018) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: