Key result
The DragonFly-T transcatheter tricuspid valve clip system successfully reduced severe tricuspid regurgitation to mild (1+) and improved symptoms to functional class I at 1 month in a patient with Barlow-type tricuspid valve prolapse.
Why the study?
Tricuspid regurgitation from Barlow-type tricuspid valve prolapse is rare and underreported, and the use of tricuspid TEER in treating this condition is not well documented.
Does the DragonFly-T transcatheter edge-to-edge repair system safely and effectively reduce severe tricuspid regurgitation in a patient with Barlow-type tricuspid valve prolapse?
Case Report (n=1)
No
Does the DragonFly-T transcatheter edge-to-edge repair system safely and effectively reduce severe tricuspid regurgitation in a patient with Barlow-type tricuspid valve prolapse?
The DragonFly-T transcatheter tricuspid valve clip system successfully and safely reduced severe tricuspid regurgitation in a high-risk patient with complex Barlow-type tricuspid valve prolapse.
Answers are grounded in this paper and cite their sources.
May inform TEER decisions in rare Barlow prolapse; leaves open durability and generalizability.
BACKGROUND: Tricuspid regurgitation caused by tricuspid valve prolapse, especially Barlow-type prolapse, is a rare and underreported condition. Recent advancements in tricuspid transcatheter edge-to-edge repair (TEER) have provided new treatment options for patients who are poor candidates for surgery, yet the use of tricuspid TEER in treating Barlow-type tricuspid valve prolapse is not well documented. CASE SUMMARY: This case report presents a patient treated with the novel DragonFly-T transcatheter tricuspid valve clip system for Barlow-type tricuspid valve prolapse. Postoperatively, the patient's symptoms improved, and the reduction in regurgitation remained stable. DISCUSSION: The case provides valuable insight into expanding the applications of tricuspid TEER for challenging tricuspid valve pathologies.
No takes yet. Share an insight, caveat, or question.
Ren et al. (2025) conducted a case report in Severe tricuspid regurgitation caused by Barlow-type tricuspid valve prolapse (n=1). DragonFly-T Transcatheter Tricuspid Valve Clip System was evaluated on Reduction in tricuspid regurgitation. The DragonFly-T transcatheter tricuspid valve clip system successfully reduced severe tricuspid regurgitation to mild (1+) and improved symptoms to functional class I at 1 month in a patient with Barlow-type tricuspid valve prolapse.
Synapse has enriched 10 related papers. Consider them for comparative context: