To compare the detection rate of renal cortical defects with Tc-99m dimercaptosuccinic acid (DMSA) using triple-detector SPECT, pinhole, and planar cortical scintigraphy, the authors prospectively studied 80 kidneys in 40 patients (26 males, 14 females) who ranged in age from 3 months to 26 years (mean: 7.5 years). They found single or multiple definite defects in 30 kidneys using SPECT, 23 using pinhole imaging, and 17 using planar imaging (McNemar's test, two-tailed, P < 0.001 and P = 0.03, respectively). SPECT was significantly better than pinhole imaging at demonstrating definite defects (P = 0.008). This study indicates that SPECT, and to a lesser extent pinhole, are superior to planar imaging for conclusively demonstrating renal cortical defects.
No takes yet. Share an insight, caveat, or question.
Applegate et al. (1997) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: