Answers are grounded in this paper and cite their sources.
Two factors which add greatly to the difficulty of interpretation of radiographs are distortion and great variation in thickness or density of various anatomical parts included in single radiographs, as for instance, the toes and ankle, or regions adjacent to the diaphragm. Much has been accomplished to minimize distortion and irregularity of density, by making multiple exposures from various angles and by the employment of greater plate-target distance. With a view of further reducing the effects of distortion and variation of density we attempted during the past year the development of some new apparatus of unusual type. We were especially interested in the making of clear radiographs of large portions of the spine, which would more accurately portray the relation of its various parts. My first idea was to develop a method of shifting the tube up and down the spine, making a number of radiographs of small portions of the spine on the same plate in such a manner that they would fit together in a composite picture. The idea of moving the tube during exposure was considered, but not attempted; because of the probable loss of detail. Co-operation of the research department of the Kelley-Koett Company was secured, and an apparatus for the work was constructed under the direction of Mr. W. W. Mowry. Mr. Mowry also suggested moving the tube while exposure was being made, and he carried out some experiments. After analyzing the results of this work, our present apparatus was completed by the Kelley-Koett Company, and considerable experimentation has been carried out. The results are in some respects very encouraging, and we believe the idea has certain advantages which deserve the attention of the progressive radiologist. The apparatus (Fig. 1) consists of a regular radiographic table with a side rail and arm to hold an x-ray tube at a plate-target distance of 25 inches. This tube is driven lengthwise of the table at varying speeds by a motor-driven worm gear. Instead of the regular circular cone, an adjustable slit is arranged between the tube and patient to take the place of the cone. Hence, as a tube is passed from one end of the table to the other a beam of x-rays like a narrow sheet, or line of x-rays traverses the patient. In other words, the tube moves over the part to be radiographed while the exposure is being made. The apparatus is so arranged that all the plate is protected by lead, except that narrow strip which is being exposed. The protecting material is supported by an arm under the table top between the patient and the plate, and this is secured to the tube, moving at the same speed as the tube. This single slit serves the same purpose as a narrow Bucky in absorbing secondary rays. In this way all the central beam of x-rays passes through the body and reaches the plate from the same angle.
No takes yet. Share an insight, caveat, or question.
Robert H. Millwee (1937) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: