High-impulse current and voltage measurement in high-voltage technology and plasma physics is generally accompanied by high-level electromagnetic interference. This paper gives an analysis of various avenues of conducted and radiated interference entry showing that cable braid and cabinet currents represent major source of interference. A better understanding of interference propagation leads to the systematic evaluation of counter measures which can be undertaken.
No takes yet. Share an insight, caveat, or question.
Schwab et al. (1974) studied this question.