Answers are grounded in this paper and cite their sources.
The article presents data on modern methods of diagnosis and monitoring of keratoconus. The main pathognomonic signs are described according to routine research methods: biomicroscopy, viso-, autoref- and keratometry, as well as special research methods such as keratotopography, keratotomography, optical coherence tomography, aberrometry, confocal microscopy and the study of biomechanical properties of the cornea. The “gold standard” in the diagnosis of subclinical keratoconus, today, is scanning keratotomography on a Scheimpfl ug camera with the Belin-Ambrósio enhanced ectasia protocol embedded in the device
No takes yet. Share an insight, caveat, or question.
V.V. Averich (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: