Key result
Time between measurements, hypertension, lower baseline flow-mediated dilation, and less lab experience independently predicted larger variability in repeated brachial artery flow-mediated dilation measurements.
Observational (n=672)
Yes
Brachial artery flow-mediated dilation demonstrates good reproducibility, though variability is independently increased by longer intervals between measurements, hypertension, lower baseline FMD, and less laboratory experience.
OBJECTIVES: Brachial artery flow-mediated dilation (FMD) is a popular technique to examine endothelial function in humans. Identifying volunteer and methodological factors related to variation in FMD is important to improve measurement accuracy and applicability. METHODS: Volunteer-related and methodology-related parameters were collected in 672 volunteers from eight affiliated centres worldwide who underwent repeated measures of FMD. All centres adopted contemporary expert-consensus guidelines for FMD assessment. After calculating the coefficient of variation (%) of the FMD for each individual, we constructed quartiles (n = 168 per quartile). Based on two regression models (volunteer-related factors and methodology-related factors), statistically significant components of these two models were added to a final regression model (calculated as β-coefficient and R). This allowed us to identify factors that independently contributed to the variation in FMD%. RESULTS: Median coefficient of variation was 17.5%, with healthy volunteers demonstrating a coefficient of variation 9.3%. Regression models revealed age (β = 0.248, P < 0.001), hypertension (β = 0.104, P < 0.001), dyslipidemia (β = 0.331, P < 0.001), time between measurements (β = 0.318, P < 0.001), lab experience (β = -0.133, P < 0.001) and baseline FMD% (β = 0.082, P < 0.05) as contributors to the coefficient of variation. After including all significant factors in the final model, we found that time between measurements, hypertension, baseline FMD% and lab experience with FMD independently predicted brachial artery variability (total R = 0.202). CONCLUSION: Although FMD% showed good reproducibility, larger variation was observed in conditions with longer time between measurements, hypertension, less experience and lower baseline FMD%. Accounting for these factors may improve FMD% variability.
No takes yet. Share an insight, caveat, or question.
Mil et al. (2016) conducted an observational in Endothelial function assessment (n=672). Subject- and methodology-related factors was evaluated on Coefficient of variation (CV) of repeated FMD measurements. Time between measurements, hypertension, lower baseline flow-mediated dilation, and less lab experience independently predicted larger variability in repeated brachial artery flow-mediated dilation measurements.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: