Why the study?
Routine use of TEE during liver transplant surgery has increased, but its effects on patient outcome remain unknown, leaving anesthesiologists uncertain whether to undergo training and adopt it.
Does transesophageal echocardiography (TEE) monitoring improve diagnosis and clinical management safely in patients undergoing liver transplant surgery?
Systematic Review
Does transesophageal echocardiography (TEE) monitoring improve diagnosis and clinical management safely in patients undergoing liver transplant surgery?
TEE is an effective and safe monitoring tool during liver transplant surgery that aids in rapid diagnosis and guides clinical management.
Supports TEE monitoring in liver transplantation for rapid diagnosis and management; extends cardiac surgery safety data to this population.
More anesthesiologists are routinely using transesophageal echocardiography (TEE) during liver transplant surgery, but the effects on patient outcome are unknown. Transplant anesthesiologists are therefore uncertain if they should undergo additional training and adopt TEE. In response to these clinical questions, the Society for the Advancement of Transplant Anesthesia appointed experts in liver transplantation and who are certified in TEE to evaluate all available published evidence on the topic. The aim was to produce a summary with greater explanatory power than individual reports to guide transplant anesthesiologists in their decision to use TEE. An exhaustive search recovered 51 articles of uncontrolled clinical observations. Topics chosen for this study were effectiveness and safety because they were a major or minor topic in all articles. The pattern of clinical use was a common topic and was included to provide contextual information. Summarized observations showed effectiveness as the ability to make a new and unexpected diagnosis and to direct the choice of clinical management. These were reported in each stage of liver transplant surgery. There were observations that TEE facilitated rapid diagnosis of life-threatening conditions difficult to identify with other types of monitoring commonly used in the operating room. Real-time diagnosis by TEE images made anesthesiologists confident in their choice of interventions, especially those with a high risk of complications such as use of anticoagulants for intracardiac thrombosis. The summarized observations in this systematic review suggest that TEE is an effective form of monitoring with a safety profile similar to that in cardiac surgery patients.
No takes yet. Share an insight, caveat, or question.
Marchi et al. (2020) conducted a systematic review in Liver transplant surgery. Transesophageal echocardiography (TEE) was evaluated on Effectiveness and safety. Transesophageal echocardiography during liver transplant surgery was found to be an effective monitoring tool with a favorable safety profile, based on a systematic review of 51 articles.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: