Key result
HMDS vapor deposition for in vitro gliding assays requires <30 minutes of preparation time compared to >12 hours for nitrocellulose, providing a flat surface with similar actin gliding speed.
Why the study?
Nitrocellulose-coated coverslips for in vitro gliding assays are time-consuming to prepare, yield rough surfaces, and have high background autofluorescence.
HMDS vapor deposition is a faster, flatter, and lower-autofluorescence alternative to nitrocellulose for in vitro gliding assays of molecular motors.
May streamline gliding assay setup; leaves open validation for biosensing devices.
In vitro gliding assay is a well-established assay for determining the activity of protein motors, such as actin-associated myosins and microtubule-associated kinesins and dyneins. In one of the conventional methods, protein motors are immobilized onto a nitrocellulose-coated coverslip and it propels actin filaments in the presence of ATP. Gliding assays also serve as the foundation for protein-motor-based nanotechnological devices such as biosensing and sorting. However, the preparation of nitrocellulose-coated coverslips is time-consuming and produces rough surfaces. Furthermore, the nitrocellulose film exhibits high background autofluorescence, which can be a problem in single-molecule measurements. Here, we investigated the use of hexamethyldisilazane (HMDS) to study actomyosin function and characterized its physical properties on glass coverslips and glass capillary tubes. We showed that the total preparation time to coat a coverslip with HMDS is <30 minutes, which is 1 order of magnitude faster than the >12-hour protocol for coating glass surfaces with nitrocellulose. In contrast to nitrocellulose film, HMDS vapor deposition is effortless and provides an atomically flat surface with low autofluorescence. In addition, HMDS does not interfere with myosin function, which is indicated by the similar actin gliding speed when compared with nitrocellulose. Our results show that HMDS vapor deposition is a more favorable surface treatment to nitrocellulose for in vitro gliding assay.
No takes yet. Share an insight, caveat, or question.
Tengganu et al. (2021) studied this question. Hexamethyldisilazane (HMDS) vapor deposition vs. Nitrocellulose coating was evaluated on Preparation time, surface roughness, autofluorescence, and actin gliding speed. HMDS vapor deposition for in vitro gliding assays requires <30 minutes of preparation time compared to >12 hours for nitrocellulose, providing a flat surface with similar actin gliding speed.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: