Answers are grounded in this paper and cite their sources.
This study aimed to provide a low-cost technique for virus detection in wastewater by improving an aluminum hydroxide adsorption–precipitation method. The releasing efficiency of viruses trapped by the aluminum hydroxide precipitates was improved by adding ethylenediaminetetraacetic acid disodium salt (EDTA-2Na) to dissolve the precipitates at a Na 2 EDTA·2H 2 O:AlCl 3 molar ratio of 1.8–3.6. The recovery rates of the improved method for seven viruses, including SARS-CoV-2-abEN pseudovirus and six animal viruses, were 5.9–22.3% in tap water and 4.9–35.1% in wastewater. Rotavirus A (9.0–4.5 × 10 3 copies/mL), porcine circovirus type 2 (5.8–6.4 × 10 5 copies/mL), and porcine parvovirus (5.6–2.7 × 10 4 copies/mL) were detected in China’s pig farm wastewater, while rotavirus A (2.0 × 10 3 copies/mL) was detected in hospital wastewater. SARS-CoV-2 was detected in hospital wastewater (8.4 × 10 2 to 1.4 × 10 4 copies/mL), sewage (6.4 × 10 to 2.3 × 10 3 copies/mL), and river water (6.6 × 10 to 9.3 × 10 copies/mL) in Nepal. The method was automized, with a rate of recovery of 4.8 ± 1.4% at a virus concentration of 10 2 copies/mL. Thus, the established method could be used for wastewater-based epidemiology with sufficient sensitivity in coping with the COVID-19 epidemic and other virus epidemics.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: