The modeling and steady-state performance of single-phase induction generators based on the principles of harmonic balance is set forth in this paper. Magnetizing flux linkage saturation and flux dependent core loss resistances are included. Experimental results are provided to justify the analytical approach and steady-state calculations.>
No takes yet. Share an insight, caveat, or question.
Ojo et al. (1995) studied this question.