Key result
A novel liquid chromatography-mass spectrometry method detected ticagrelor and its metabolite M8 with good sensitivity and precision in the ranges of 10-100 µM and 5-50 µM, respectively.
Why the study?
Few studies have clarified population differences in the pharmacokinetics and pharmacodynamics of ticagrelor between Caucasians and Asians, motivating a simple quantification method for ticagrelor and its active metabolite M8.
A novel, cost-effective LC/MS method was developed to quantify ticagrelor and its active metabolite M8, which may facilitate future pharmacokinetic and pharmacodynamic studies.
May facilitate ticagrelor PK/PD research; leaves open any clinical adoption pending validation.
Ticagrelor is an oral antiplatelet agent that has been approved for preventing de novo and recurrent acute coronary syndrome. To date, only a few studies have attempted to clarify population differences in the pharmacokinetics and pharmacodynamics of ticagrelor between Caucasians and Asians. Our aim was to develop a simple quantification method for ticagrelor and its pharmacologically active metabolite M8 (AR-C124910XX) in human plasma and urine. First, we concisely synthesized M8 from ticagrelor via a five-step sequence: the hydroxyethyl group of ticagrelor was removed by bromination and subsequent zinc-mediated chemoselective reduction. Then, we developed a simple liquid chromatography–mass spectrometry method using ticlopidine as an internal standard. Ticagrelor, M8, and internal standard were separated with a reverse-phase C 18 column, and ticagrelor and M8 were detected at m/ z [+] of 523.25 and 479.25, respectively, with good sensitivity and precision in the concentration ranges of 10 to 100 µM and 5 to 50 µM, respectively. This novel liquid chromatography–mass spectrometry system may be attractive to investigators in private laboratories because it is less costly than liquid chromatography/mass spectrometry/mass spectrometry systems. Our method is expected to accelerate further clinical studies on the disposition and pharmacodynamics of ticagrelor.
No takes yet. Share an insight, caveat, or question.
Suzuki et al. (2021) studied this question. Liquid chromatography-mass spectrometry (LC/MS) was evaluated on Quantification of ticagrelor and M8. A novel liquid chromatography-mass spectrometry method detected ticagrelor and its metabolite M8 with good sensitivity and precision in the ranges of 10-100 µM and 5-50 µM, respectively.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: