Answers are grounded in this paper and cite their sources.
Simultaneous and nonperturbing measurements using a multislit streak camera, two high-voltage probes, and a Rogowski coil were carried out to enable an equivalent-circuit analysis to be made of a plasma-focus discharge in the run-down phase. A lead current is assumed to flow to the insulator. Calculations show that maximum constant values of diode voltage, V/sub p/ approximately=5.3 kV, and pinch current, I/sub p/ approximately=200 kA, are attained during the run-down phase; the product of these two parameters shows an upper limit in the input power. From the multislit streak camera, a limiting run-down speed, v/sub z/ approximately=9.2 cm/ mu s, for the plasma sheath is observed, which suggests a constant rate of change of inductance. These observations indicate a steady-state operation of the plasma focus for this duration.>
No takes yet. Share an insight, caveat, or question.
Tou et al. (1989) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: