Answers are grounded in this paper and cite their sources.
In this paper, two different piezoelectric transducers-a ceramic piezoelectric, lead zirconate titanate (PZT), and a polymeric piezoelectric, polyvinylidene fluoride (PVDF)-were compared in terms of energy that could be harvested during locomotion activities. The transducers were placed into a tight suit in proximity of the main body joints. Initial testing was performed by placing the transducers on the neck, shoulder, elbow, wrist, hip, knee and ankle; then, five locomotion activities-walking, walking up and down stairs, jogging and running-were chosen for the tests. The values of the power output measured during the five activities were in the range 6 µW-74 µW using both transducers for each joint.
No takes yet. Share an insight, caveat, or question.
Proto et al. (2016) studied this question.