The green continuum of Hg vapor in a low current, positive column discharge has been found to be greatly enhanced by the presence of a considerable pressure of a rare gas (e.g., 50-mm argon). The effect is most striking for lower Hg pressures (e.g., at 50^∘{}C). At 215^∘{}C the light efficiency of the continuum reaches 41 lu/w. The continuum extends from 4000 to 6400A; its maximum occurs at 5130A at 115^∘{} and shifts toward the violet at higher temperatures. Very small amounts of gas impurity, e.g., 40 parts per million of N₂ increase the brightness and also the voltage; larger amounts, e.g., 150 ppm N₂, quench the brightness almost completely.
No takes yet. Share an insight, caveat, or question.
Kenty et al. (1953) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: