This is the authors' abstract. We don't add key points for this paper.
Time-resolved scanning transmission x-ray microscopy measurements were performed to study the current-induced magnetization switching mechanism in nanopillars exhibiting strong perpendicular magnetic anisotropy. This technique provides both short-time (70 ps) and high-spatial (25 nm) resolutions. Direct imaging of the magnetization demonstrates that, after an incubation time of ~1.3 ns, a 100×300 nm² ellipsoidal device switches in ~1 ns via a central domain nucleation and opposite propagation of two domain walls toward the edges. High domain-wall velocities on the order of 100 m/s are measured. Micromagnetic simulations are shown to be in good agreement with experimental results and provide insight into magnetization dynamics during the incubation and reversal periods.
No takes yet. Share an insight, caveat, or question.
Bernstein et al. (2011) studied this question.