Answers are grounded in this paper and cite their sources.
3D finite element analysis of long term aging and sudden accidental degeneration processes is presented for physiologic compression load. A systematic modeling and simulation is applied for analyzing the separated and mutual effect of certain material moduli of the components of lumbar motion segments on the mechanical behaviour and stability of the segment during the long time and sudden degeneration processes. It was concluded that due to their smallest stiffness the younger segments with light degeneration are the most vulnerable during both the long-time age-related and the sudden overload-related degeneration. DOI: 10.17489/biohun/2013/1/25
No takes yet. Share an insight, caveat, or question.
Márta et al. (2013) studied this question.