Answers are grounded in this paper and cite their sources.
Summary This study presents early results of the clinical experience of computer-assisted surgery (CAS) applied to percutaneous iliosacral screwing compared with an historical series of patients treated by percutaneous fluoroscopy. Four patients were instrumented with a CAS, with 10 screws being inserted. Thirty patients were treated by percutaneous fluoroscopic screwing, with 51 screws inserted. The follow up included operative time, the parameters of the radiation exposure, the neurologic examination, the screw placement evaluation on computed tomography scan, antalgic drug consumption, pain, Majeed grading, and the loosening implants. In the CAS group, the radiation time by patient was 0.35 minutes and by screw 0.14 minutes. No outside bone trajectories and no postoperative neurologic deficit were found. In the fluoroscopic group, the radiation time by patient was 1.03 minutes and 0.6 minutes by screw. Twelve screws had outside bone trajectories. In 7 patients, iatrogenic neurologic deficit was found. The average operative time was 50 minutes in the CAS group and 35 minutes in the fluoroscopic group. The present CAS technique shows better placement of iliosacral screws without outside bone trajectories and lower radiation exposure.
No takes yet. Share an insight, caveat, or question.
Tonetti et al. (2003) studied this question.