This work investigates the robustness of an ultrathin backside-illuminated (BSI) silicon-on-insulator (SOI) single-photon avalanche diode (SPAD) against gamma-ray irradiation for space applications. Experimental results demonstrate a breakdown voltage shift in the studied SPAD from 10.17 to 9.95 V after a total ionizing dose (TID) of 132 krad(Si). An increase in dark count rate (DCR) from 1490 to 2700 cps/μm2 at 1 V excess bias is shown at this dose. TCAD simulations explain the role of the oxide-trapped charges, induced by irradiation in the insulating layer surrounding the active region, on the SPAD performance. These trapped charges shift the peak electric field, leading to premature breakdown while the extension of the active area affected by impact ionization increases the DCR. Further simulations show that implementing a perimeter-gated structure and reducing oxide thickness can effectively mitigate these effects by leveraging capacitive effects, preventing a breakdown voltage shift. The perimeter gate (PG) lowers the simulated DCR after irradiation from 2700 to 1365 cps/μm2, thereby enhancing the radiation resilience of ultrathin SOI SPADs beyond a TID of 132 krad(Si).
No takes yet. Share an insight, caveat, or question.
Klauner et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: