Answers are grounded in this paper and cite their sources.
In this article, a new high-voltage and high-frequency power supply for ozone generation is introduced. This circuit uses a single switch and works in the resonant mode with the help of transformer magnetizing and leakage inductances (without adding a distinct resonant inductor), a separate resonant capacitor, and a step-up transformer to generate high voltage output. The simulation results demonstrate that with a 250-V dc input, a 7.9-kV pulse with 1.66 μs pulse-width is generated at the output. A hardware prototype with 250-V dc input and 7.3-kV output pulse is developed. The pulse repetition frequency can go up to 15 kHz, and the efficiency of 84% is achieved. The simulation, experimental, and microbiological test results are presented to validate the proposed converter and its operating principle.
No takes yet. Share an insight, caveat, or question.
Abkenar et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: