Key result
A novel Self-Adapt Co-design approach using an RLS adaptive filter on an FPGA achieved an average Signal-to-Noise Ratio improvement of 89.78% for ECG noise removal.
Why the study?
Obtaining a noise-free ECG recording is difficult due to various types of interference, making an effective filter essential for accurate diagnosis of heart muscle disorders.
Answers are grounded in this paper and cite their sources.
A novel FPGA-based RLS adaptive filter co-design effectively removes ECG noise, improving SNR by nearly 90% while significantly reducing power consumption for potential use in wearable devices.
• Developed a novel low-complexity ECG filter to enhance signal quality in diagnosing heart disorders. • Implemented the Recursive Least-Squares Adaptive (RLS) algorithm on an FPGA for active noise reduction. • Applied different adaptation algorithms, enhancing versatility across various use cases. • Achieved an impressive 89.78 % improvement in signal-to-noise ratio through the Self-Adapt Co-design approach for effective ECG noise removal. Doctors diagnose various heart muscle disorders by continuously analyzing ELECTROCARDIOGRAM (ECG) signals. Obtaining a noise-free ECG recording is difficult due to various types of interference, making an effective filter essential for accurate diagnosis. This paper introduces a novel, low-complexity filter designed to enhance ECG signal quality. The proposed method involves partitioning the implementation of the Recursive Least Squares (RLS) adaptive filter between a Microblaze soft processor and hardware resources within a Field Programmable Gate Array (FPGA). The hardware component is responsible for creating a Finite Impulse Response (FIR) filter, while the adaptive processing is handled by the soft processor. This configuration makes the filter adaptable, allowing it to work with various algorithms for a wide range of applications. The co-design was tested for ECG noise removal, achieving an average Signal-to-Noise Ratio (SNR) improvement of 89.78 %. Offloading adaptive tasks to the soft processor reduced power consumption by 56.2 %, making it suitable for integration with ECG sensors in wearable body networks.
No takes yet. Share an insight, caveat, or question.
Mahmood et al. (2024) studied ECG noise removal. Self-Adapt Co-design approach (RLS adaptive filter on FPGA and Microblaze soft processor) was evaluated on Signal-to-Noise Ratio (SNR) improvement. A novel Self-Adapt Co-design approach using an RLS adaptive filter on an FPGA achieved an average Signal-to-Noise Ratio improvement of 89.78% for ECG noise removal.
Synapse has enriched 10 related papers. Consider them for comparative context: