Key result
Real-time aspiration dual-lumen microcatheters boost parallel wire technical success to 98% vs conventional devices.
Why the study?
Suboptimal parallel wire technique success rates in CTO PCI result primarily from progressive subintimal hematoma expansion during procedural maneuvers.
Does a real-time aspiration-enabled dual-lumen microcatheter improve technical success rates of the parallel wire technique in patients undergoing chronic total occlusion percutaneous coronary intervention?
Cohort (n=100)
Yes
Does a real-time aspiration-enabled dual-lumen microcatheter improve technical success rates of the parallel wire technique in patients undergoing chronic total occlusion percutaneous coronary intervention?
The novel real-time aspiration-enabled dual-lumen microcatheter significantly improves the technical success of the parallel wire technique in complex CTO PCI by mitigating subintimal hematoma expansion.
Answers are grounded in this paper and cite their sources.
May support aspiration microcatheter use in CTO parallel wiring; leaves open need for randomized confirmation.
BACKGROUND: Suboptimal parallel wire technique (PWT) success rates result primarily from progressive subintimal hematoma expansion during procedural maneuvers in chronic total occlusion (CTO) percutaneous coronary intervention (PCI). OBJECTIVES: The aim of this study was to evaluate the procedural outcomes of a novel dual over-the-wire engineered, subintimal hematoma aspiration-enabled dual-lumen microcatheter (DLMC) assisted PWT in CTO PCI. METHODS: One hundred consecutive CTO PCI cases using the PWT were retrospectively analyzed, comparing outcomes between a conventional DLMC (Conv-DLMC) and a H.STARFISH (real-time [RT] aspiration DLMC) assisted PWT. RESULTS: Reattempt cases constituted 31.0% of all procedures (31 of 100). In the RT aspiration DLMC group, 13 of 50 cases (26.0%) crossed over after Conv-DLMC failure. Hematoma aspiration was performed in 70.0% (35 of 50) of the RT aspiration DLMC group and in 100% of cases (13 of 13) switched from failed Conv-DLMC attempts. PWT success rates were significantly higher with RT aspiration DLMC (98.0% [49 of 50]; 95% CI: 89.4%-99.9%) vs Conv-DLMC (78.0% [39 of 50]; 95% CI: 64.0%-88.5%) (P < 0.001). Although median PWT duration showed no significant difference (RT aspiration DLMC vs Conv-DLMC: 22.0 minutes [Q1-Q3: 10.8-51.0 minutes] vs 23.5 minutes [Q1-Q3: 12.0-36.3 minutes]; P = 0.735), prolonged PWT attempts (>45 minutes) occurred more frequently in the RT aspiration DLMC group than the Conv-DLMC group (30.0% [15 of 50] vs 12.0% [6 of 50]; P = 0.027), with a maximum duration of 147 minutes recorded in the RT aspiration DLMC group. Meanwhile, the Conv-DLMC group required a higher rate of strategy switching to retrograde approach (4.0% [2 of 50] vs 22.0% [11 of 50]; P = 0.007). No major complications occurred in either group. CONCLUSIONS: The RT aspiration DLMC was able to improve PWT success rates in CTO PCI and enable prolonged PWT attempts because of its RT hematoma aspiration capability.
No takes yet. Share an insight, caveat, or question.
Zhong et al. (2026) conducted a cohort in Chronic total occlusion (CTO) undergoing percutaneous coronary intervention (PCI) using parallel wire technique (PWT) (n=100). Real-time aspiration-enabled dual-lumen microcatheter (H.STARFISH) vs. Conventional dual-lumen microcatheter (Conv-DLMC) was evaluated on Technical success rate of the PWT (successful wire re-entry into the distal true lumen) (p=<0.001). The real-time aspiration-enabled dual-lumen microcatheter improved parallel wire technique success rates to 98.0% compared to 78.0% with conventional microcatheters.
Synapse has enriched 10 related papers. Consider them for comparative context: